본문 바로가기 주메뉴 바로가기

제품소개

Products

Contact Us 031-970-1816
견적문의

제품 상세 정보

Home > 제품 상세 정보
제품명
SDLVA-2D5G4D9G-60-50MV
PDF 파일 다운로드

제품 상세 사양 Product specification

Model: SDLVA-2D5G4D9G-60-50MV   PMI Model No. SDLVA-2D5G4D9G-60-50MV is a successive detection log video amplifier operating over the frequency range of 2.5 to 4.9GHz. It has a dynamic range of -60 to 0dBm and a log slope of 50.5 ±5% mV/dB.  The unit has input power handling of +20dBm CW max with a duty cycle of 0 to 100%.  Quick Links: (click the links below for additional information) Product Feature Test Report Specifications: Frequency Range 2.5 to 4.9GHz Dynamic Range -60 to 0dBm Input RF Power Handling +20dBm CW max Duty Cycle 0 to 100% Pulse Width 100ns to CW VSWR 2.0:1 at J1 and J2 (50 Ohms ±2 nominal) RF Gain 50dB min RF Saturated Power +15dBm RF Output max 1dB gain compression to be +6dBm min Tangential Sensitivity -70dBm min (J3) Log Video Load Imp. 93 ±5 Ohms Log Video Linearity +1.5dB max over input dynamic range Log Slope 50.5 ±5% mV/dB Absolute Log Video Output 0.423 ±0.075 with RF input of -55dBm AVG Log Video Output 0.17V ±0.05V with RF Input of -60dBm 3.2V ±0.05V with RF Input of 0dBm Flatness <4.0dB @ -60 to -50dBm Input <6.0dB @ -50 to 0dBm Input No Sig Output Voltage >140 mV Below Output Voltage at -60dBm Rise Time 20ns (10 to 90%) Fall/ Recovery Time 50ns (90 to 10%) Pulse Delay 90% RF Input to 90% Log Video Pulse @ <35ns Log Video Output CW & Pulse Leading Edge Overshoot 1.0dB up to -35dBm 2.5dB from -35 to 0dBm 35ns to recover within 0.6dB of final value DC Power +12VDC ±3%, 200mV P-P ripple @ 500mA max -12VDC ±3%, 200mV P-P ripple @ 180mA max Weight 1.4 oz max Environmental Ratings: Temperature:  -20ºC to +85ºC Operating  -65ºC to +95ºC Non-Operating  Altitude:  -1300 to +35,000 FT Per  MIL-STD-202F Method 105C  Thermal Shock:  MIL-STD-202F, Method 107G Cond. A-1  Humidity:  MIL-STD-202F, Method 103B Cond. A  Fungus:  MIL-STD-810C, Method 508.2  Salt Fog:  MIL-STD-202F, Method 101D Cond. B  Sand and Dust:  MIL-STD-202F, Method 110A  Fluid Exposure:  Resistant to and shall not form toxic  by-products when exposed to:  A) Isopropyl Alcohol (TT-I-735)  B) 1,1,1 Trichloroethane, Vapor Decreasing  Solvent (MIL-T-81533)  C) Freon TF  D) Methanol (O-M-232)  E) Coolanol 20, 25 and 25R  F) Hydraulic Oil (MIL-H-5606 or 87257)  G) Water  Shock:  MIL-STD-202F, Method 213B Cond. J  Acoustic Noise:  60 min test in normal mounting configuration,  survival use table 1  Random Vibration:  MIL-STD-202F, Method 214A  Per the vibration curve in Figure 1 on Product  Feature  Sinusodial Search/Dwell:  Unit to meet electrical requirements during/  after test described in Table 2 on Product  Feature.  Resonance search is for a duration  of 15 mins per axis duration of the dwell test  shall be at 133Hz at an input level  corresponding to the level specified in each  of the three mutually perpendicular axes  Altitude:  MIL-STD-202F, Method 212A Cond. A  at a 20G level  Explosive Atmosphere:  MIL-STD-810C, Method 511.1,  Procedures I through III  Electromagnetic Interference:  Paragraph 5.016 of MIL-STD-461 and the  requirements identified in RE102